Power relay
Power relay
DIN rail mounting
Für Verteilereinbau
CO: 1
Rated current AC-1: 16 A
Rated current DC-1: 16 A
Rated voltage AC: 250 V
Rated voltage DC: 25 V
Minimum current: 10 mA
Minimum voltage: 10 V
E = On delay
A = Off delay
W = One shot leading edge
N = One shot trailing edge
K = Puls shaping
B = Blinker (Pulse start)
B1 = Blinker (Pulse start, trailing pulse)
S = Step-switching
LS = Step-switching
Power relay
DIN rail mounting
Für Verteilereinbau
Solid state AC: 1
Rated current AC-1: 2 A
Rated voltage AC: 250 V
Minimum current: 50 mA
Minimum voltage: 12 V
E = On delay
A = Off delay
W = One shot leading edge
N = One shot trailing edge
K = Puls shaping
B = Blinker (Pulse start)
B1 = Blinker (Pulse start, trailing pulse)
S = Step-switching
LS = Step-switching
Power relay
Control relay
DIN rail mounting
Für Verteilereinbau
Solid state DC: 1
Rated current DC-1: 5 A
Rated voltage DC: 24 V
Minimum current: 1 mA
Minimum voltage: 1 V
E = On delay
A = Off delay
W = One shot leading edge
N = One shot trailing edge
K = Puls shaping
B = Blinker (Pulse start)
B1 = Blinker (Pulse start, trailing pulse)
S = Step-switching
LS = Step-switching
High-power relay
DIN rail mounting
Für Verteilereinbau
NO: 1
Rated current AC-1: 16 A
Rated current DC-1: 16 A
Rated voltage AC: 250 V
Rated voltage DC: 25 V
Minimum current: 100 mA
Minimum voltage: 12 V
E = On delay
A = Off delay
W = One shot leading edge
N = One shot trailing edge
K = Puls shaping
B = Blinker (Pulse start)
B1 = Blinker (Pulse start, trailing pulse)
S = Step-switching
LS = Step-switching
Power relay
DIN rail mounting
Für Verteilereinbau
CO: 1
Rated current AC-1: 16 A
Rated current DC-1: 16 A
Rated voltage AC: 250 V
Rated voltage DC: 25 V
Minimum current: 10 mA
Minimum voltage: 10 V
E = On delay
A = Off delay
L = Puls shaping (retrigger)
M = Puls shaping
B2 = Blinker (Interval start)
G = On delay single shot
H = On delay single shot
Power relay
DIN rail mounting
Für Verteilereinbau
Solid state AC: 1
Rated current AC-1: 2 A
Rated voltage AC: 250 V
Minimum current: 50 mA
Minimum voltage: 12 V
E = On delay
A = Off delay
L = Puls shaping (retrigger)
M = Puls shaping
B2 = Blinker (Interval start)
G = On delay single shot
H = On delay single shot
Power relay
Control relay
DIN rail mounting
Für Verteilereinbau
Solid state DC: 1
Rated current DC-1: 5 A
Rated voltage DC: 24 V
Minimum current: 1 mA
Minimum voltage: 1 V
E = On delay
A = Off delay
L = Puls shaping (retrigger)
M = Puls shaping
B2 = Blinker (Interval start)
G = On delay single shot
H = On delay single shot
Power relay
DIN rail mounting
Für Verteilereinbau
CO: 1
Rated current AC-1: 16 A
Rated current DC-1: 16 A
Rated voltage AC: 250 V
Rated voltage DC: 25 V
Minimum current: 10 mA
Minimum voltage: 10 V
F = On and off delay
Q = One shot leading and trailing edge
G = On delay single shot
H = On delay single shot
I = Repeat cycle timer (Pulse start)
P = Repeat cycle start (Interval start)
Power relay
DIN rail mounting
Für Verteilereinbau
Solid state AC: 1
Rated current AC-1: 2 A
Rated voltage AC: 250 V
Minimum current: 50 mA
Minimum voltage: 12 V
F = On and off delay
Q = One shot leading and trailing edge
G = On delay single shot
H = On delay single shot
I = Repeat cycle timer (Pulse start)
P = Repeat cycle start (Interval start)
Power relay
Control relay
DIN rail mounting
Für Verteilereinbau
Solid state DC: 1
Rated current DC-1: 4 A
Rated voltage DC: 24 V
Minimum current: 1 mA
Minimum voltage: 1 V
F = On and off delay
Q = One shot leading and trailing edge
G = On delay single shot
H = On delay single shot
I = Repeat cycle timer (Pulse start)
P = Repeat cycle start (Interval start)