• C7-T22 | Signal relay, 2 pole

    C7-T22BX/UC24V  R
    C7-T22BX/UC24V  R
    Signal relay
    C7-T22BX/UC24V R
    CONTROL RELAY TWIN GOLDCONTACT
    - Changeover contacts, twin contacts
    - Contact material AgNi + 5 µm Au

    CO: 2
    Rated current AC-1: 6 A
    Rated current DC-1: 6 A
    Rated voltage AC: 250 V
    Rated voltage DC: 30 V
    Minimum current: 1 mA
    Minimum voltage: 5 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 24 V
    Nominal supply voltage max.: 24 V

    CEURLloydsEACSeismischCCC

    Status LED (X)
    Bridge rectifier (B)

  • C7-T22BX/UC48V  R
    C7-T22BX/UC48V  R
    Signal relay
    C7-T22BX/UC48V R
    CONTROL RELAY TWIN GOLDCONTACT
    - Changeover contacts, twin contacts
    - Contact material AgNi + 5 µm Au

    CO: 2
    Rated current AC-1: 6 A
    Rated current DC-1: 6 A
    Rated voltage AC: 250 V
    Rated voltage DC: 30 V
    Minimum current: 1 mA
    Minimum voltage: 5 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 48 V
    Nominal supply voltage max.: 48 V

    CEURLloydsEACSeismischCCC

    Status LED (X)
    Bridge rectifier (B)

  • C7-T22D/DC110V  R
    C7-T22D/DC110V  R
    Signal relay
    C7-T22D/DC110V R
    CONTROL RELAY TWIN GOLDCONTACT
    - Changeover contacts, twin contacts
    - Contact material AgNi + 5 µm Au

    CO: 2
    Rated current AC-1: 6 A
    Rated current DC-1: 6 A
    Rated voltage AC: 250 V
    Rated voltage DC: 30 V
    Minimum current: 1 mA
    Minimum voltage: 5 V
    Versorgungsspannung: DC
    Nominal supply voltage min.: 110 V
    Nominal supply voltage max.: 110 V

    CEURLloydsEACSeismischCCC

    Free wheeling diode (D and F)

  • C7-T22X/AC230V  R
    C7-T22X/AC230V  R
    Signal relay
    C7-T22X/AC230V R
    CONTROL RELAY TWIN GOLDCONTACT
    - Changeover contacts, twin contacts
    - Contact material AgNi + 5 µm Au

    CO: 2
    Rated current AC-1: 6 A
    Rated current DC-1: 6 A
    Rated voltage AC: 250 V
    Rated voltage DC: 30 V
    Minimum current: 1 mA
    Minimum voltage: 5 V
    Versorgungsspannung: AC
    Nominal supply voltage min.: 230 V
    Nominal supply voltage max.: 230 V

    CEURLloydsEACSeismischCCC

    Status LED (X)

  • C7-T22X/DC24V  R
    C7-T22X/DC24V  R
    Signal relay
    C7-T22X/DC24V R
    CONTROL RELAY TWIN GOLDCONTACT
    - Changeover contacts, twin contacts
    - Contact material AgNi + 5 µm Au

    CO: 2
    Rated current AC-1: 6 A
    Rated current DC-1: 6 A
    Rated voltage AC: 250 V
    Rated voltage DC: 30 V
    Minimum current: 1 mA
    Minimum voltage: 5 V
    Versorgungsspannung: DC
    Nominal supply voltage min.: 24 V
    Nominal supply voltage max.: 24 V

    CEURLloydsEACSeismischCCC

    Status LED (X)