• C5-M10 | Power relay, 1 pole

    C5-M10/AC115V  R
    C5-M10/AC115V  R
    High-power relay
    C5-M10/AC115V R
    POWER RELAY MAGNETIC BLOW OUT
    - NO contact, contact opening 3 mm, blowout magnet
    - Contact material AgNi
    - 16 A @ 400 V AC / 30 V DC

    NO: 1
    Rated current AC-1: 16 A
    Rated current DC-1: 10 A
    Rated current DC-13: 2 A
    Rated voltage AC: 400 V
    Rated voltage DC: 220 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: AC
    Nominal supply voltage min.: 115 V
    Nominal supply voltage max.: 115 V

    CEURLloydsEACCCC

  • C5-M10/AC120V 60HZ  R
    C5-M10/AC120V 60HZ  R
    High-power relay
    C5-M10/AC120V 60HZ R
    POWER RELAY MAGNETIC BLOW OUT
    - NO contact, contact opening 3 mm, blowout magnet
    - Contact material AgNi
    - 16 A @ 400 V AC / 30 V DC

    NO: 1
    Rated current AC-1: 16 A
    Rated current DC-1: 10 A
    Rated current DC-13: 2 A
    Rated voltage AC: 400 V
    Rated voltage DC: 220 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: AC
    Nominal supply voltage min.: 120 V
    Nominal supply voltage max.: 120 V

    CEURLloydsEACCCC

  • C5-M10/AC230V  R
    C5-M10/AC230V  R
    High-power relay
    C5-M10/AC230V R
    POWER RELAY MAGNETIC BLOW OUT
    - NO contact, contact opening 3 mm, blowout magnet
    - Contact material AgNi
    - 16 A @ 400 V AC / 30 V DC

    NO: 1
    Rated current AC-1: 16 A
    Rated current DC-1: 10 A
    Rated current DC-13: 2 A
    Rated voltage AC: 400 V
    Rated voltage DC: 220 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: AC
    Nominal supply voltage min.: 230 V
    Nominal supply voltage max.: 230 V

    CEURLloydsEACCCC

  • C5-M10/AC24V  R
    C5-M10/AC24V  R
    High-power relay
    C5-M10/AC24V R
    POWER RELAY MAGNETIC BLOW OUT
    - NO contact, contact opening 3 mm, blowout magnet
    - Contact material AgNi
    - 16 A @ 400 V AC / 30 V DC

    NO: 1
    Rated current AC-1: 16 A
    Rated current DC-1: 10 A
    Rated current DC-13: 2 A
    Rated voltage AC: 400 V
    Rated voltage DC: 220 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: AC
    Nominal supply voltage min.: 24 V
    Nominal supply voltage max.: 24 V

    CEURLloydsEACCCC

  • C5-M10/AC400V  R
    C5-M10/AC400V  R
    High-power relay
    C5-M10/AC400V R
    POWER RELAY MAGNETIC BLOW OUT
    - NO contact, contact opening 3 mm, blowout magnet
    - Contact material AgNi
    - 16 A @ 400 V AC / 30 V DC

    NO: 1
    Rated current AC-1: 16 A
    Rated current DC-1: 10 A
    Rated current DC-13: 2 A
    Rated voltage AC: 400 V
    Rated voltage DC: 220 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: AC
    Nominal supply voltage min.: 400 V
    Nominal supply voltage max.: 400 V

    CELloydsEACCCC

  • C5-M10/DC110V  R
    C5-M10/DC110V  R
    High-power relay
    C5-M10/DC110V R
    POWER RELAY MAGNETIC BLOW OUT
    - NO contact, contact opening 3 mm, blowout magnet
    - Contact material AgNi
    - 16 A @ 400 V AC / 30 V DC

    NO: 1
    Rated current AC-1: 16 A
    Rated current DC-1: 10 A
    Rated current DC-13: 2 A
    Rated voltage AC: 400 V
    Rated voltage DC: 220 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: DC
    Nominal supply voltage min.: 110 V
    Nominal supply voltage max.: 110 V

    CEURLloydsEACCCC

  • C5-M10/DC120-125V  R
    C5-M10/DC120-125V  R
    High-power relay
    C5-M10/DC120-125V R
    POWER RELAY MAGNETIC BLOW OUT
    - NO contact, contact opening 3 mm, blowout magnet
    - Contact material AgNi
    - 16 A @ 400 V AC / 30 V DC

    NO: 1
    Rated current AC-1: 16 A
    Rated current DC-1: 10 A
    Rated current DC-13: 2 A
    Rated voltage AC: 400 V
    Rated voltage DC: 220 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: DC
    Nominal supply voltage min.: 120 V
    Nominal supply voltage max.: 125 V

    CEURLloydsEACCCC

  • C5-M10/DC12V  R
    C5-M10/DC12V  R
    High-power relay
    C5-M10/DC12V R
    POWER RELAY MAGNETIC BLOW OUT
    - NO contact, contact opening 3 mm, blowout magnet
    - Contact material AgNi
    - 16 A @ 400 V AC / 30 V DC

    NO: 1
    Rated current AC-1: 16 A
    Rated current DC-1: 10 A
    Rated current DC-13: 2 A
    Rated voltage AC: 400 V
    Rated voltage DC: 220 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: DC
    Nominal supply voltage min.: 12 V
    Nominal supply voltage max.: 12 V

    CEURLloydsEACCCC

  • C5-M10/DC220V  R
    C5-M10/DC220V  R
    High-power relay
    C5-M10/DC220V R
    POWER RELAY MAGNETIC BLOW OUT
    - NO contact, contact opening 3 mm, blowout magnet
    - Contact material AgNi
    - 16 A @ 400 V AC / 30 V DC

    NO: 1
    Rated current AC-1: 16 A
    Rated current DC-1: 10 A
    Rated current DC-13: 2 A
    Rated voltage AC: 400 V
    Rated voltage DC: 220 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: DC
    Nominal supply voltage min.: 220 V
    Nominal supply voltage max.: 220 V

    CEURLloydsEACCCC

  • C5-M10/DC240V  R
    C5-M10/DC240V  R
    High-power relay
    C5-M10/DC240V R
    POWER RELAY MAGNETIC BLOW OUT
    - NO contact, contact opening 3 mm, blowout magnet
    - Contact material AgNi
    - 16 A @ 400 V AC / 30 V DC

    NO: 1
    Rated current AC-1: 16 A
    Rated current DC-1: 10 A
    Rated current DC-13: 2 A
    Rated voltage AC: 400 V
    Rated voltage DC: 220 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: DC
    Nominal supply voltage min.: 240 V
    Nominal supply voltage max.: 240 V

    CEURLloydsEACCCC

  • C5-M10/DC24V  R
    C5-M10/DC24V  R
    High-power relay
    C5-M10/DC24V R
    POWER RELAY MAGNETIC BLOW OUT
    - NO contact, contact opening 3 mm, blowout magnet
    - Contact material AgNi
    - 16 A @ 400 V AC / 30 V DC

    NO: 1
    Rated current AC-1: 16 A
    Rated current DC-1: 10 A
    Rated current DC-13: 2 A
    Rated voltage AC: 400 V
    Rated voltage DC: 220 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: DC
    Nominal supply voltage min.: 24 V
    Nominal supply voltage max.: 24 V

    CEURLloydsEACCCC

  • C5-M10/DC250V  R
    C5-M10/DC250V  R
    High-power relay
    C5-M10/DC250V R
    POWER RELAY MAGNETIC BLOW OUT
    - NO contact, contact opening 3 mm, blowout magnet
    - Contact material AgNi
    - 16 A @ 400 V AC / 30 V DC

    NO: 1
    Rated current AC-1: 16 A
    Rated current DC-1: 10 A
    Rated current DC-13: 2 A
    Rated voltage AC: 400 V
    Rated voltage DC: 220 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: DC
    Nominal supply voltage min.: 250 V
    Nominal supply voltage max.: 250 V

    CEURLloydsEACCCC