• MRU11 | Voltage monitoring relay (1 phase), 1 pole

    MRU11/UC110-240V
    MRU11/UC110-240V
    Control relay
    MRU11/UC110-240V
    VOLTAGE MONITORING RELAY 1-P
    - Changeover contact
    - Contact material AgNi
    - Measuring range 0.1-480 V AC / 0.1-690 V DC
    - For installation in electrical distributor

    DIN rail mounting
    Für Verteilereinbau

    CO: 1
    Rated current AC-1: 6 A
    Rated current DC-1: 6 A
    Rated voltage AC: 250 V
    Rated voltage DC: 30 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 110 V
    Nominal supply voltage max.: 240 V

    1 phase
    Voltage monitoring AC
    Voltage monitoring DC
    Phase loss monitoring
    Phase sequence monitoring
    Phase angle monitoring
    Frequency monitoring
    Treshold exceeded (over)
    Theshold undershot (under)
    Window function (inside)
    Window function (outside)
    Alarm on-delay
    Alarm off-delay
    Threshold selectable

    CEULEAC

  • MRU11/UC12-48V
    MRU11/UC12-48V
    Control relay
    MRU11/UC12-48V
    VOLTAGE MONITORING RELAY 1-P
    - Changeover contact
    - Contact material AgNi
    - Measuring range 0.1-480 V AC / 0.1-690 V DC
    - For installation in electrical distributor

    DIN rail mounting
    Für Verteilereinbau

    CO: 1
    Rated current AC-1: 6 A
    Rated current DC-1: 6 A
    Rated voltage AC: 250 V
    Rated voltage DC: 30 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 12 V
    Nominal supply voltage max.: 48 V

    1 phase
    Voltage monitoring AC
    Voltage monitoring DC
    Phase loss monitoring
    Phase sequence monitoring
    Phase angle monitoring
    Frequency monitoring
    Treshold exceeded (over)
    Theshold undershot (under)
    Window function (inside)
    Window function (outside)
    Alarm on-delay
    Alarm off-delay
    Threshold selectable

    CEULEAC

  • MRU11R/UC110-240V
    MRU11R/UC110-240V
    Control relay
    MRU11R/UC110-240V
    VOLTAGE MONITORING RELAY 1-P
    - Changeover contact
    - Contact material AgNi
    - Measuring range 0.1-480 V AC / 0.1-690 V DC
    - For installation in electrical distributor

    DIN rail mounting
    Für Verteilereinbau

    CO: 1
    Rated current AC-1: 6 A
    Rated current DC-1: 6 A
    Rated voltage AC: 250 V
    Rated voltage DC: 30 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 110 V
    Nominal supply voltage max.: 240 V

    1 phase
    Voltage monitoring AC
    Voltage monitoring DC
    Phase loss monitoring
    Phase sequence monitoring
    Phase angle monitoring
    Frequency monitoring
    Treshold exceeded (over)
    Theshold undershot (under)
    Window function (inside)
    Window function (outside)
    Alarm on-delay
    Alarm off-delay
    Threshold selectable

    CEULEAC

  • MRU11R/UC12-48V
    MRU11R/UC12-48V
    Control relay
    MRU11R/UC12-48V
    VOLTAGE MONITORING RELAY 1-P
    - Changeover contact
    - Contact material AgNi
    - Measuring range 0.1-480 V AC / 0.1-690 V DC
    - For installation in electrical distributor

    DIN rail mounting
    Für Verteilereinbau

    CO: 1
    Rated current AC-1: 6 A
    Rated current DC-1: 6 A
    Rated voltage AC: 250 V
    Rated voltage DC: 30 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 12 V
    Nominal supply voltage max.: 48 V

    1 phase
    Voltage monitoring AC
    Voltage monitoring DC
    Phase loss monitoring
    Phase sequence monitoring
    Phase angle monitoring
    Frequency monitoring
    Treshold exceeded (over)
    Theshold undershot (under)
    Window function (inside)
    Window function (outside)
    Alarm on-delay
    Alarm off-delay
    Threshold selectable

    CEULEAC