• AM1/UC110-240V  S
    AM1/UC110-240V  S
    Power relay
    AM1/UC110-240V S
    TIME DELAY RELAY COMAT
    - Changeover contact
    - Contact material AgNi
    - 10 A @ 250 V AC / 10 A @ 25 V DC
    - For installation in electrical distributor
    - Time functions: E, W, B, B2

    DIN rail mounting
    Für Verteilereinbau

    CO: 1
    Rated current AC-1: 10 A
    Rated current DC-1: 10 A
    Rated voltage AC: 250 V
    Rated voltage DC: 25 V
    Minimum current: 10 mA
    Minimum voltage: 12 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 110 V
    Nominal supply voltage max.: 240 V

    E = On delay
    W = One shot leading edge
    B = Blinker (Pulse start)
    B2 = Blinker (Interval start)

    CEUREAC

  • AM1/UC24-60V  S
    AM1/UC24-60V  S
    Power relay
    AM1/UC24-60V S
    TIME DELAY RELAY COMAT
    - Changeover contact
    - Contact material AgNi
    - 10 A @ 250 V AC / 10 A @ 25 V DC
    - For installation in electrical distributor
    - Time functions: E, W, B, B2

    DIN rail mounting
    Für Verteilereinbau

    CO: 1
    Rated current AC-1: 10 A
    Rated current DC-1: 10 A
    Rated voltage AC: 250 V
    Rated voltage DC: 25 V
    Minimum current: 10 mA
    Minimum voltage: 12 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 24 V
    Nominal supply voltage max.: 60 V

    E = On delay
    W = One shot leading edge
    B = Blinker (Pulse start)
    B2 = Blinker (Interval start)

    CEUREAC

  • AM2/AC220-240V  S
    AM2/AC220-240V  S
    Power relay
    AM2/AC220-240V S
    TIME DELAY RELAY COMAT
    - Changeover contact
    - Contact material AgNi
    - 10 A @ 250 V AC / 10 A @ 25 V DC
    - For installation in electrical distributor
    - Time functions: E, A, K, W

    DIN rail mounting
    Für Verteilereinbau

    CO: 1
    Rated current AC-1: 10 A
    Rated current DC-1: 10 A
    Rated voltage AC: 250 V
    Rated voltage DC: 25 V
    Minimum current: 10 mA
    Minimum voltage: 12 V
    Versorgungsspannung: AC
    Nominal supply voltage min.: 220 V
    Nominal supply voltage max.: 240 V

    E = On delay
    A = Off delay
    W = One shot leading edge
    K = Puls shaping

    CEUREAC

  • AM2/UC24-60V  S
    AM2/UC24-60V  S
    Power relay
    AM2/UC24-60V S
    TIME DELAY RELAY COMAT
    - Changeover contact
    - Contact material AgNi
    - 10 A @ 250 V AC / 10 A @ 25 V DC
    - For installation in electrical distributor
    - Time functions: E, A, K, W

    DIN rail mounting
    Für Verteilereinbau

    CO: 1
    Rated current AC-1: 10 A
    Rated current DC-1: 10 A
    Rated voltage AC: 250 V
    Rated voltage DC: 25 V
    Minimum current: 10 mA
    Minimum voltage: 12 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 24 V
    Nominal supply voltage max.: 60 V

    E = On delay
    A = Off delay
    W = One shot leading edge
    K = Puls shaping

    CEUREAC

  • AM3/AC220-240V  S
    AM3/AC220-240V  S
    Power relay
    AM3/AC220-240V S
    TIME DELAY RELAY COMAT
    - Changeover contacts
    - Contact material AgNi
    - 10 A @ 250 V AC / 10 A @ 30 V DC
    - For installation in electrical distributor
    - Time functions: E, A, K, W

    DIN rail mounting

    CO: 1
    Rated current AC-1: 10 A
    Rated current DC-1: 10 A
    Rated voltage AC: 250 V
    Rated voltage DC: 30 V
    Minimum current: 10 mA
    Minimum voltage: 12 V
    Versorgungsspannung: AC
    Nominal supply voltage min.: 220 V
    Nominal supply voltage max.: 240 V

    E = On delay
    A = Off delay
    W = One shot leading edge
    K = Puls shaping

    CEUREAC

  • AM3/UC24-60V  S
    AM3/UC24-60V  S
    Power relay
    AM3/UC24-60V S
    TIME DELAY RELAY COMAT
    - Changeover contacts
    - Contact material AgNi
    - 10 A @ 250 V AC / 10 A @ 30 V DC
    - For installation in electrical distributor
    - Time functions: E, A, K, W

    DIN rail mounting

    CO: 1
    Rated current AC-1: 10 A
    Rated current DC-1: 10 A
    Rated voltage AC: 250 V
    Rated voltage DC: 30 V
    Minimum current: 10 mA
    Minimum voltage: 12 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 24 V
    Nominal supply voltage max.: 60 V

    E = On delay
    A = Off delay
    W = One shot leading edge
    K = Puls shaping

    CEUREAC

  • C55.3/UC110-240V  R
    C55.3/UC110-240V  R
    Control relay
    C55.3/UC110-240V R
    COMAT TIMER
    - Changeover contacts
    - Contact material AgNi
    - 0.5 A @ 265 V AC / DC
    - Time functions: E, W, H, B, I, A, K, N, M, G, F, Q, U, V

    Solid state AC: 1
    Solid state DC: 1
    Rated current AC-1: 0.5 A
    Rated current DC-1: 0.5 A
    Rated voltage AC: 265 V
    Rated voltage DC: 265 V
    Minimum current: 1 mA
    Minimum voltage: 10 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 110 V
    Nominal supply voltage max.: 240 V

    E = On delay
    A = Off delay
    F = On and off delay
    W = One shot leading edge
    N = One shot trailing edge
    Q = One shot leading and trailing edge
    K = Puls shaping
    B = Blinker (Pulse start)
    G = On delay single shot
    H = On delay single shot
    I = Repeat cycle timer (Pulse start)
    P = Repeat cycle start (Interval start)
    Pulse sequence monitoring (U)
    Pulse sequence monitoring (V)

    CEEAC

  • C55.3/UC24-60V  R
    C55.3/UC24-60V  R
    Control relay
    C55.3/UC24-60V R
    COMAT TIMER
    - Changeover contacts
    - Contact material AgNi
    - 0.5 A @ 265 V AC / DC
    - Time functions: E, W, H, B, I, A, K, N, M, G, F, Q, U, V

    Solid state AC: 1
    Solid state DC: 1
    Rated current AC-1: 0.5 A
    Rated current DC-1: 0.5 A
    Rated voltage AC: 265 V
    Rated voltage DC: 265 V
    Minimum current: 1 mA
    Minimum voltage: 10 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 24 V
    Nominal supply voltage max.: 60 V

    E = On delay
    A = Off delay
    F = On and off delay
    W = One shot leading edge
    N = One shot trailing edge
    Q = One shot leading and trailing edge
    K = Puls shaping
    B = Blinker (Pulse start)
    G = On delay single shot
    H = On delay single shot
    I = Repeat cycle timer (Pulse start)
    P = Repeat cycle start (Interval start)
    Pulse sequence monitoring (U)
    Pulse sequence monitoring (V)

    CEEAC

  • C55.4/DC24V  R
    C55.4/DC24V  R
    Power relay Control relay
    C55.4/DC24V R
    COMAT TIMER
    - Changeover contacts
    - Contact material AgNi
    - 2 A @ 30 V DC
    - Time functions: E, W, H, B, I, A, K, N, M, G, F, Q, U, V

    Solid state AC: 1
    Rated current DC-1: 2 A
    Rated voltage DC: 30 V
    Minimum current: 1 mA
    Minimum voltage: 5 V
    Versorgungsspannung: DC
    Nominal supply voltage min.: 24 V
    Nominal supply voltage max.: 24 V

    E = On delay
    A = Off delay
    F = On and off delay
    W = One shot leading edge
    N = One shot trailing edge
    Q = One shot leading and trailing edge
    K = Puls shaping
    M = Puls shaping
    B = Blinker (Pulse start)
    G = On delay single shot
    H = On delay single shot
    I = Repeat cycle timer (Pulse start)
    P = Repeat cycle start (Interval start)
    Pulse sequence monitoring (U)
    Pulse sequence monitoring (V)

    CEEAC

  • C55/UC110-240V  R
    C55/UC110-240V  R
    Power relay
    C55/UC110-240V R
    COMAT TIMER
    - Changeover contacts
    - Contact material AgNi
    - 5 A @ 250 V AC / 5 A @ 25 V DC
    - Time functions: E, W, H, B, I, A, K, N, M, G, F, Q, U, V

    CO: 2
    Rated current AC-1: 5 A
    Rated current DC-1: 5 A
    Rated voltage AC: 250 V
    Rated voltage DC: 35 V
    Minimum current: 10 mA
    Minimum voltage: 12 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 110 V
    Nominal supply voltage max.: 240 V

    E = On delay
    A = Off delay
    F = On and off delay
    W = One shot leading edge
    N = One shot trailing edge
    Q = One shot leading and trailing edge
    K = Puls shaping
    M = Puls shaping
    B = Blinker (Pulse start)
    G = On delay single shot
    H = On delay single shot
    I = Repeat cycle timer (Pulse start)
    P = Repeat cycle start (Interval start)
    Pulse sequence monitoring (U)
    Pulse sequence monitoring (V)

    CEEACSeismisch

  • C55/UC24-60V  R
    C55/UC24-60V  R
    Power relay
    C55/UC24-60V R
    COMAT TIMER
    - Changeover contacts
    - Contact material AgNi
    - 5 A @ 250 V AC / 5 A @ 25 V DC
    - Time functions: E, W, H, B, I, A, K, N, M, G, F, Q, U, V

    CO: 2
    Rated current AC-1: 5 A
    Rated current DC-1: 5 A
    Rated voltage AC: 250 V
    Rated voltage DC: 35 V
    Minimum current: 10 mA
    Minimum voltage: 12 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 24 V
    Nominal supply voltage max.: 60 V

    E = On delay
    A = Off delay
    F = On and off delay
    W = One shot leading edge
    N = One shot trailing edge
    Q = One shot leading and trailing edge
    K = Puls shaping
    M = Puls shaping
    B = Blinker (Pulse start)
    G = On delay single shot
    H = On delay single shot
    I = Repeat cycle timer (Pulse start)
    P = Repeat cycle start (Interval start)
    Pulse sequence monitoring (U)
    Pulse sequence monitoring (V)

    CEEACSeismisch

  • C56/UC110-240V  R
    C56/UC110-240V  R
    Power relay
    C56/UC110-240V R
    COMAT TIMER
    - Changeover contacts
    - Contact material AgNi
    - 5 A @ 250 V AC / 5 A @ 35 V DC
    - Time functions: E, W, H, B, I, P, A, L, N, M, G, F, Q, U, V

    CO: 2
    Rated current AC-1: 5 A
    Rated current DC-1: 5 A
    Rated voltage AC: 250 V
    Rated voltage DC: 35 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 110 V
    Nominal supply voltage max.: 240 V

    E = On delay
    A = Off delay
    F = On and off delay
    W = One shot leading edge
    N = One shot trailing edge
    Q = One shot leading and trailing edge
    K = Puls shaping
    M = Puls shaping
    B = Blinker (Pulse start)
    G = On delay single shot
    H = On delay single shot
    I = Repeat cycle timer (Pulse start)
    P = Repeat cycle start (Interval start)
    Pulse sequence monitoring (U)
    Pulse sequence monitoring (V)

    CEEAC