• CIM3/UC24-240V
    CIM3/UC24-240V
    Power relay
    CIM3/UC24-240V
    MULTIFUNCTION DEVICE COMAT
    - Changeover contact
    - Contact material AgNi
    - 16 A @ 250 V AC
    - For installation in electrical distributor
    - Time functions: F, Q, G, H, I, P

    DIN rail mounting
    Für Verteilereinbau

    CO: 1
    Rated current AC-1: 16 A
    Rated current DC-1: 16 A
    Rated voltage AC: 250 V
    Rated voltage DC: 25 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 24 V
    Nominal supply voltage max.: 240 V

    F = On and off delay
    Q = One shot leading and trailing edge
    G = On delay single shot
    H = On delay single shot
    I = Repeat cycle timer (Pulse start)
    P = Repeat cycle start (Interval start)

    CEUREAC

  • CIM32/UC24-240V
    CIM32/UC24-240V
    Power relay
    CIM32/UC24-240V
    MULTIFUNCTION DEVICE COMAT
    - Solid state
    - Triac
    - 2 A @ 250 V AC
    - For installation in electrical distributor
    - Time functions: F, Q, G, H, I, P

    DIN rail mounting
    Für Verteilereinbau

    Solid state AC: 1
    Rated current AC-1: 2 A
    Rated voltage AC: 250 V
    Minimum current: 50 mA
    Minimum voltage: 12 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 24 V
    Nominal supply voltage max.: 240 V

    F = On and off delay
    Q = One shot leading and trailing edge
    G = On delay single shot
    H = On delay single shot
    I = Repeat cycle timer (Pulse start)
    P = Repeat cycle start (Interval start)

    CEEAC

  • CIM32R/UC24-240V
    CIM32R/UC24-240V
    RailwayPower relay
    CIM32R/UC24-240V
    MULTIFUNCTION DEVICE COMAT
    - Solid state
    - Triac
    - 2 A @ 250 V AC
    - For installation in electrical distributor
    - Time functions: F, Q, G, H, I, P

    DIN rail mounting
    Für Verteilereinbau

    Solid state AC: 1
    Rated current AC-1: 2 A
    Rated voltage AC: 250 V
    Minimum current: 50 mA
    Minimum voltage: 12 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 24 V
    Nominal supply voltage max.: 240 V

    F = On and off delay
    Q = One shot leading and trailing edge
    G = On delay single shot
    H = On delay single shot
    I = Repeat cycle timer (Pulse start)
    P = Repeat cycle start (Interval start)

    CEEACRailway

  • CIM33/UC24-240V
    CIM33/UC24-240V
    Power relay Control relay
    CIM33/UC24-240V
    MULTIFUNCTION DEVICE COMAT
    - Solid state
    - Mosfet
    - 5 A @ 24 V DC
    - For installation in electrical distributor
    - Time functions: F, Q, G, H, I, P

    DIN rail mounting
    Für Verteilereinbau

    Solid state DC: 1
    Rated current DC-1: 4 A
    Rated voltage DC: 24 V
    Minimum current: 1 mA
    Minimum voltage: 1 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 24 V
    Nominal supply voltage max.: 240 V

    F = On and off delay
    Q = One shot leading and trailing edge
    G = On delay single shot
    H = On delay single shot
    I = Repeat cycle timer (Pulse start)
    P = Repeat cycle start (Interval start)

    CEEAC

  • CIM33R/UC24-240V
    CIM33R/UC24-240V
    RailwayPower relay Control relay
    CIM33R/UC24-240V
    MULTIFUNCTION DEVICE COMAT
    - Solid state
    - Mosfet
    - 5 A @ 24 V DC
    - For installation in electrical distributor
    - Time functions: F, Q, G, H, I, P

    DIN rail mounting
    Für Verteilereinbau

    Solid state DC: 1
    Rated current DC-1: 4 A
    Rated voltage DC: 24 V
    Minimum current: 1 mA
    Minimum voltage: 1 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 24 V
    Nominal supply voltage max.: 240 V

    F = On and off delay
    Q = One shot leading and trailing edge
    G = On delay single shot
    H = On delay single shot
    I = Repeat cycle timer (Pulse start)
    P = Repeat cycle start (Interval start)

    CEEACRailway

  • CIM3R/UC24-240V
    CIM3R/UC24-240V
    RailwayPower relay
    CIM3R/UC24-240V
    MULTIFUNCTION DEVICE COMAT
    - Changeover contact
    - Contact material AgNi
    - 16 A @ 250 V AC
    - For installation in electrical distributor
    - Time functions: F, Q, G, H, I, P

    DIN rail mounting
    Für Verteilereinbau

    CO: 1
    Rated current AC-1: 16 A
    Rated current DC-1: 16 A
    Rated voltage AC: 250 V
    Rated voltage DC: 25 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 24 V
    Nominal supply voltage max.: 240 V

    F = On and off delay
    Q = One shot leading and trailing edge
    G = On delay single shot
    H = On delay single shot
    I = Repeat cycle timer (Pulse start)
    P = Repeat cycle start (Interval start)

    CEUREACShockRailway

  • CM2/UC110-240V  S
    CM2/UC110-240V  S
    Power relay
    CM2/UC110-240V S
    TIME DELAY RELAY COMAT
    - Changeover contact
    - Contact material AgNi
    - 6 A @ 250 V AC
    - Time functions: E, A, K, W

    DIN rail mounting

    NO: 1
    CO: 1
    Rated current AC-1: 6 A
    Rated current DC-1: 4.16 A
    Rated voltage AC: 250 V
    Rated voltage DC: 24 V
    Minimum current: 10 mA
    Minimum voltage: 12 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 110 V
    Nominal supply voltage max.: 240 V

    CEUREAC

  • CM2/UC24-60V  S
    CM2/UC24-60V  S
    Power relay
    CM2/UC24-60V S
    TIME DELAY RELAY COMAT
    - Changeover contact
    - Contact material AgNi
    - 6 A @ 250 V AC
    - Time functions: E, A, K, W

    DIN rail mounting

    NO: 1
    CO: 1
    Rated current AC-1: 6 A
    Rated current DC-1: 4.16 A
    Rated voltage AC: 250 V
    Rated voltage DC: 24 V
    Minimum current: 10 mA
    Minimum voltage: 12 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 24 V
    Nominal supply voltage max.: 60 V

    CEUREAC

  • CM3/DC12-24V  S
    CM3/DC12-24V  S
    Power relay
    CM3/DC12-24V S
    TIME DELAY RELAY COMAT
    - Changeover contact
    - Contact material AgNi
    - 5 A @ 250 V AC
    - Time functions: E, A, K, N, B, B1, W

    DIN rail mounting

    CO: 2
    Rated current AC-1: 5 A
    Rated current DC-1: 5 A
    Rated voltage AC: 250 V
    Rated voltage DC: 30 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: DC
    Nominal supply voltage min.: 12 V
    Nominal supply voltage max.: 24 V

    CEUREAC

  • CM3/DC24-48/AC24-240V  S
    CM3/DC24-48/AC24-240V  S
    Power relay
    CM3/DC24-48/AC24-240V S
    TIME DELAY RELAY COMAT
    - Changeover contact
    - Contact material AgNi
    - 5 A @ 250 V AC
    - Time functions: E, A, K, N, B, B1, W

    DIN rail mounting

    CO: 2
    Rated current AC-1: 5 A
    Rated current DC-1: 5 A
    Rated voltage AC: 250 V
    Rated voltage DC: 30 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: DC
    Nominal supply voltage min.: 24 V
    Nominal supply voltage max.: 48 V

    CEUREAC

  • CPF11/DC24V  S
    CPF11/DC24V  S
    Control relay
    CPF11/DC24V S
    PULSE LENGTHENER COMAT
    - Solid state
    - PNP transistor
    - 2 A @ 32 V DC
    - Time functions: A, K, L

    DIN rail mounting

    Solid state DC: 1
    Rated current DC-1: 0.8 A
    Rated voltage DC: 32 V
    Versorgungsspannung: DC
    Nominal supply voltage min.: 24 V
    Nominal supply voltage max.: 24 V

    A = Off delay
    K = Puls shaping
    L = Puls shaping (retrigger)

    CEUR

  • CRV4/UC24-240V  S
    CRV4/UC24-240V  S
    Power relay
    CRV4/UC24-240V S
    COMAT TIME DELAY RELAY
    - Changeover contact
    - Contact material AgNi
    - 6 A @ 250 V AC
    - For installation in electrical distributor

    DIN rail mounting
    Für Verteilereinbau

    CO: 1
    Rated current AC-1: 6 A
    Rated current DC-1: 6 A
    Rated voltage AC: 250 V
    Rated voltage DC: 30 V
    Minimum current: 10 mA
    Minimum voltage: 10 V
    Versorgungsspannung: UC
    Nominal supply voltage min.: 24 V
    Nominal supply voltage max.: 230 V

    E = On delay
    A = Off delay
    F = On and off delay
    W = One shot leading edge
    N = One shot trailing edge
    Q = One shot leading and trailing edge
    K = Puls shaping
    L = Puls shaping (retrigger)
    M = Puls shaping
    B = Blinker (Pulse start)
    B1 = Blinker (Pulse start, trailing pulse)
    B2 = Blinker (Interval start)
    G = On delay single shot
    H = On delay single shot
    S = Step-switching
    LS = Step-switching

    CEUREACShock