Filter products
Filter products
AL1/AC220-240V
- Staircase switch
- NO contact
- Contact material AgNi
- 10 A @ 250 V AC
- For installation in electrical distributor
- Time function: L
- NO contact
- Contact material AgNi
- 10 A @ 250 V AC
- For installation in electrical distributor
- Time function: L
AL4/AC220-240V
- Staircase switch
- NO contact, pre-run contact
- Contact material AgSnO2 + W
- 10 A @ 250 V AC
- For installation in electrical distributor
- Time functions: L, LS, S
- NO contact, pre-run contact
- Contact material AgSnO2 + W
- 10 A @ 250 V AC
- For installation in electrical distributor
- Time functions: L, LS, S
AM2/AC220-240V
- Changeover contact
- Contact material AgNi
- 10 A @ 250 V AC / 10 A @ 25 V DC
- For installation in electrical distributor
- Time functions: E, A, K, W
- Contact material AgNi
- 10 A @ 250 V AC / 10 A @ 25 V DC
- For installation in electrical distributor
- Time functions: E, A, K, W
AM3/AC220-240V
- 1 pole
- Changeover contacts
- Contact material AgNi
- 10 A @ 250 V AC / 10 A @ 30 V DC
- For installation in electrical distributor
- Time functions: E, A, K, W
- Changeover contacts
- Contact material AgNi
- 10 A @ 250 V AC / 10 A @ 30 V DC
- For installation in electrical distributor
- Time functions: E, A, K, W
AM3/UC24-60V
- 1 pole
- Changeover contacts
- Contact material AgNi
- 10 A @ 250 V AC / 10 A @ 30 V DC
- For installation in electrical distributor
- Time functions: E, A, K, W
- Changeover contacts
- Contact material AgNi
- 10 A @ 250 V AC / 10 A @ 30 V DC
- For installation in electrical distributor
- Time functions: E, A, K, W
CIM1/UC24-240V
- 1 pole
- Changeover contact
- Contact material AgNi
- Max 16 A @ 250 V AC / 30 V DC
- For installation in electrical distributor
- Time functions: E, A, K, N, B1, S, LS, B, W
- Changeover contact
- Contact material AgNi
- Max 16 A @ 250 V AC / 30 V DC
- For installation in electrical distributor
- Time functions: E, A, K, N, B1, S, LS, B, W
CIM12/UC24-240V
- 1 pole
- Solid state
- Triac
- Max 2 A @ 250 V AC
- For installation in electrical distributor
- Time functions: E, A, K, N, B1, S, LS, B, W
- Solid state
- Triac
- Max 2 A @ 250 V AC
- For installation in electrical distributor
- Time functions: E, A, K, N, B1, S, LS, B, W
CIM12R/UC24-240V
- 1 pole
- Solid state
- Triac
- Max 2 A @ 250 V AC
- For installation in electrical distributor
- Time functions: E, A, K, N, B1, S, LS, B, W
- Solid state
- Triac
- Max 2 A @ 250 V AC
- For installation in electrical distributor
- Time functions: E, A, K, N, B1, S, LS, B, W
CIM13R/UC24-240V
- 1 pole
- Solid state
- Mosfet
- Max 5 A @ 24 V AC
- For installation in electrical distributor
- Time functions: E, A, K, N, B1, S, LS, B, W
- Solid state
- Mosfet
- Max 5 A @ 24 V AC
- For installation in electrical distributor
- Time functions: E, A, K, N, B1, S, LS, B, W
CIM14/UC24-240V
- 1 pole
- NO contact, pre-run contact
- Contact material AgSnO2 + W
- Max 16 A @ 250 V AC / 30 V DC
- For installation in electrical distributor
- Time functions: E, A, K, N, B1, S, LS, B, W
- NO contact, pre-run contact
- Contact material AgSnO2 + W
- Max 16 A @ 250 V AC / 30 V DC
- For installation in electrical distributor
- Time functions: E, A, K, N, B1, S, LS, B, W
CIM1R/UC24-240V
- 1 pole
- Changeover contact
- Contact material AgNi
- Max 16 A @ 250 V AC / 30 V DC
- For installation in electrical distributor
- Time functions: E, A, K, N, B1, S, LS, B, W
- Changeover contact
- Contact material AgNi
- Max 16 A @ 250 V AC / 30 V DC
- For installation in electrical distributor
- Time functions: E, A, K, N, B1, S, LS, B, W
CIM2/UC24-240V
- 1 pole
- Changeover contact
- Contact material AgNi
- Max 16 A @ 250 V AC / 30 V DC
- For installation in electrical distributor
- Time functions: E, A, L, M, G, B2, H
- Changeover contact
- Contact material AgNi
- Max 16 A @ 250 V AC / 30 V DC
- For installation in electrical distributor
- Time functions: E, A, L, M, G, B2, H
CIM2R/UC24-240V
- 1 pole
- Changeover contact
- Contact material AgNi
- Max 16 A @ 250 V AC / 30 V DC
- For installation in electrical distributor
- Time functions: E, A, L, M, G, B2, H
- Changeover contact
- Contact material AgNi
- Max 16 A @ 250 V AC / 30 V DC
- For installation in electrical distributor
- Time functions: E, A, L, M, G, B2, H
CIM3/UC24-240V
- 1 pole
- Changeover contact
- Contact material AgNi
- Max 16 A @ 250 V AC / 30 V DC
- For installation in electrical distributor
- Time functions: F, Q, G, H, I, P
- Changeover contact
- Contact material AgNi
- Max 16 A @ 250 V AC / 30 V DC
- For installation in electrical distributor
- Time functions: F, Q, G, H, I, P
CIM32R/UC24-240V
- 1 pole
- Solid state
- Triac
- Max 2 A @ 250 V AC
- For installation in electrical distributor
- Time functions: F, Q, G, H, I, P
- Solid state
- Triac
- Max 2 A @ 250 V AC
- For installation in electrical distributor
- Time functions: F, Q, G, H, I, P
CIM33R/UC24-240V
- 1 pole
- Solid state
- Mosfet
- Max 5 A @ 24 V DC
- For installation in electrical distributor
- Time functions: F, Q, G, H, I, P
- Solid state
- Mosfet
- Max 5 A @ 24 V DC
- For installation in electrical distributor
- Time functions: F, Q, G, H, I, P
CIM3R/UC24-240V
- 1 pole
- Changeover contact
- Contact material AgNi
- Max 16 A @ 250 V AC / 30 V DC
- For installation in electrical distributor
- Time functions: F, Q, G, H, I, P
- Changeover contact
- Contact material AgNi
- Max 16 A @ 250 V AC / 30 V DC
- For installation in electrical distributor
- Time functions: F, Q, G, H, I, P
CM2/UC110-240V
- 2-polig
- CO contact, NO contact
- Contact material AgNi
- 6 A @ 250 V AC
- Time functions: E, A, K, W
- CO contact, NO contact
- Contact material AgNi
- 6 A @ 250 V AC
- Time functions: E, A, K, W
CM3/DC12-24V
- 2 pole
- Changeover contact
- Contact material AgNi
- 5 A @ 250 V AC
- Time functions: E, A, K, N, B, B1, W
- Changeover contact
- Contact material AgNi
- 5 A @ 250 V AC
- Time functions: E, A, K, N, B, B1, W
CM3/DC24-48/AC24-240V
- 2 pole
- Changeover contact
- Contact material AgNi
- 5 A @ 250 V AC
- Time functions: E, A, K, N, B, B1, W
- Changeover contact
- Contact material AgNi
- 5 A @ 250 V AC
- Time functions: E, A, K, N, B, B1, W
CRV4/UC24-240V
- 1 pole
- Changeover contact
- Contact material AgNi
- 6 A @ 250 V AC
- For installation in electrical distributor
- Time functions: E, A, K, N, M, B1, F, G, Q, L, S, LS, W, B, B2, H
- Changeover contact
- Contact material AgNi
- 6 A @ 250 V AC
- For installation in electrical distributor
- Time functions: E, A, K, N, M, B1, F, G, Q, L, S, LS, W, B, B2, H