C301.04/DC24V
Control relay C301.04, 3 coils, 3 x NO contacts, monostable
NO-contact 5 A, 250 VAC
Free-wheeling diode and reverse polarity protection LED status indicator as standard Control relay for universal use in industrial control engineering and in installation applications in accordance with DIN 43880.
- Also suitable for use in electronic control systems (inductive voltage limiting)
- Easy-to-wire large-capacity terminals
- A component of the ComatReleco DIN control unit system.
NO-contact 5 A, 250 VAC
Free-wheeling diode and reverse polarity protection LED status indicator as standard Control relay for universal use in industrial control engineering and in installation applications in accordance with DIN 43880.
- Also suitable for use in electronic control systems (inductive voltage limiting)
- Easy-to-wire large-capacity terminals
- A component of the ComatReleco DIN control unit system.
| Release time | 30 ms |
|---|---|
| Pick-up voltage | 0.8 UN |
| Pick-up time | 6 ms |
| Operating voltage range | 0.8 UN … 1.2 UN |
| Power consumption AC | 3 x 0.25 VA |
| Power consumption DC | 3 X 0.25 W |
| Release voltage | ≥ 0.1 UN |
| Conductor cross section | solid wire 1 x 4 mm2, 2 x 1.5 mm2, stranded & crimped wire 1 x 2.5 mm2, 2 x 1.5 mm2 |
|---|---|
| Housing material | PA / PC |
| Ingress Protection | IP 20 |
| Mounting | TH35 (EN 60715) |
| Nominal screw torque | 0.5 Nm |
| Operation temperature | -20 … 60 °C |
| Storage temperature (no ice) | -40 … 85 °C |
| Weight | 65 g |
| Contact / coil | 2 kV / 1 min |
|---|---|
| Contact/contact | 4 kV / 1 min |
| Overvoltage category | III |
| Pollution degree | 3 |
| Rated impulse withstand voltage open contact | 1 kV / 1 min |
| Contact materials | AgAu |
|---|---|
| Electrical endurance at rated load AC-1 (cycles) | ≥ 100 000 |
| Maximum contact load AC-1 | 5 A / 250 V |
| Maximum contact load DC-1 | 5 A / 30 V |
| Mechanical endurance (cycles) | ≥ 50 000 000 |
| Number of contacts | 3 NO |
| Operating voltage | See table product references |
| Rated current | 5 A |
| Rated load AC | 1 250 VA |
| Rated load DC | 150 W |
| Recommended minimum contact load | 1 mA / 0.1 V |
| Approvals | UKCA,CE,cURus,EAC |
|---|---|
| Standards | EN 61810 |
3D-models "C301.04/DC24V"
| Release time | 30 ms |
|---|---|
| Pick-up voltage | 0.8 UN |
| Pick-up time | 6 ms |
| Operating voltage range | 0.8 UN … 1.2 UN |
| Power consumption AC | 3 x 0.25 VA |
| Power consumption DC | 3 X 0.25 W |
| Release voltage | ≥ 0.1 UN |
| Conductor cross section | solid wire 1 x 4 mm2, 2 x 1.5 mm2, stranded & crimped wire 1 x 2.5 mm2, 2 x 1.5 mm2 |
|---|---|
| Housing material | PA / PC |
| Ingress Protection | IP 20 |
| Mounting | TH35 (EN 60715) |
| Nominal screw torque | 0.5 Nm |
| Operation temperature | -20 … 60 °C |
| Storage temperature (no ice) | -40 … 85 °C |
| Weight | 65 g |
| Contact / coil | 2 kV / 1 min |
|---|---|
| Contact/contact | 4 kV / 1 min |
| Overvoltage category | III |
| Pollution degree | 3 |
| Rated impulse withstand voltage open contact | 1 kV / 1 min |
| Contact materials | AgAu |
|---|---|
| Electrical endurance at rated load AC-1 (cycles) | ≥ 100 000 |
| Maximum contact load AC-1 | 5 A / 250 V |
| Maximum contact load DC-1 | 5 A / 30 V |
| Mechanical endurance (cycles) | ≥ 50 000 000 |
| Number of contacts | 3 NO |
| Operating voltage | See table product references |
| Rated current | 5 A |
| Rated load AC | 1 250 VA |
| Rated load DC | 150 W |
| Recommended minimum contact load | 1 mA / 0.1 V |
| Approvals | UKCA,CE,cURus,EAC |
|---|---|
| Standards | EN 61810 |
Approvals
3D-models "C301.04/DC24V"